Mario Roccuzzo

Turin, Italy

Clinical case description:

> Functional restoration of implant.

> Regenerate circumferential bone defect at implant in position 44.

1
Print
<p>6 years after implant placement peri-implant bone loss is visible around the implant.</p>

6 years after implant placement peri-implant bone loss is visible around the implant.

<p>Geistlich Bio-Oss<sup>®</sup> Collagen is applied around the peri-implantitis defect.</p>

Geistlich Bio-Oss® Collagen is applied around the peri-implantitis defect.

<p>Geistlich Bio-Gide<sup>®</sup> is positioned to cover Geistlich Bio-Oss<sup>®</sup> and provide stability to the augmented site.</p>

Geistlich Bio-Gide® is positioned to cover Geistlich Bio-Oss® and provide stability to the augmented site.

<p>Clinical and radiographical situation 2.5 years post-up shows stable conditions.</p>

Clinical and radiographical situation 2.5 years post-up shows stable conditions.

Pre-surgery


							<p>6 years after implant placement peri-implant bone loss is visible around the implant.</p>

Surgery


							<p>Geistlich Bio-Oss<sup>®</sup> Collagen is applied around the peri-implantitis defect.</p>

Outcome


							<p>Geistlich Bio-Gide<sup>®</sup> is positioned to cover Geistlich Bio-Oss<sup>®</sup> and provide stability to the augmented site.</p>

Follow-up after at least 6 months


							<p>Clinical and radiographical situation 2.5 years post-up shows stable conditions.</p>